StabiframeSTABIFRAME — ossature LGS

Vertical extensions

Add a floor without demolishing, thanks to the lightness of steel.

Extending an existing building upwards imposes weight, foundation and schedule constraints. Light-gauge steel framing answers these elegantly.

Our approach

An additional storey, without heavy reinforcement.

We design the structure of the added level in light-gauge steel: load-bearing walls, floors and roof terrace or trusses. The whole is engineered to rest on the existing load-bearing elements.

The reduced weight limits foundation reinforcement. The site remains dry, fast and compact, which is decisive in dense urban environments.

We deliver numbered panels and the corresponding assembly drawings. Your crews assemble on-site without heavy cranes, according to the site logistics.

Your project

Do you have a project?

Send us your plans and questions. Our engineering office will reply with a technical hypothesis and a price estimate.

Contact us

Site photography

Study, production and assembly of the added level.

surelevation.title
Surélévation en structure LGS sur un bâtiment existant

Benefits

Why use LGS framing for vertical extensions.

Densifying existing structures rather than building new: a strategic lever for authorities and developers.

− 60 %

structural weight

Controlled weight
The surcharge on existing foundations and floors is minimised compared to concrete or masonry.

− 50 %

construction time

Low-disruption site
Screwed assembly, no curing time, no concrete mixers. Ideal for occupied sites.

+ 10 %

net internal area

Area gained
Slim walls and compact floors: more floor area for the same building footprint.
Local standards
Calculation notes adapted to the destination country: Eurocodes, snow, wind and imposed loads.

Process

Study, production and assembly of the added level.

  1. 01

    Existing diagnosis

    Drawings, photos and load-bearing capacity of current walls and floors.

  2. 02

    Design

    Grid of the added level, gables, roof, access and chimneys.

  3. 03

    Structural calculation

    Load paths, bracing, connection with the existing building.

  4. 04

    Manufacturing

    Cold-formed panels and trusses, numbered in the factory.

  5. 05

    Assembly

    Assembly drawings, lifting order, final torque check.

Related product

MaxWall Solutions

High-performance load-bearing wall for vertical extensions and demanding multi-storey structures.

View product sheet

Votre projet

Recevez une hypothèse technique et un ordre de prix.

Envoyez vos plans, la localisation et la surface approximative.

Demander une étude
Étude gratuiteÉcrire